Bakersfield based. California focused.Urgent service: call to check availability (661) 378-8738
LCP-1 DC – Transient Protector

Rice Lake · Power Conditioning

LCP-1 DC

Transient Protector

Standard features

  • Low cost, non-serviceable
  • Effective series protection for strain gauge transducers
  • Encapsulated circuitry ensures positive protection against fungus or corrosion on boards
  • Two nylon strain reliefs for 0.187 to 0.312 in (4.7 to 7.9 mm) diameter cable

Specifications

Protection Type
Four-channel series type with separate shield
Maximum Excitation Voltage Rate
18 VDC or 18 VAC
Clamping Voltage
75 VDC or 75 VAC
Clamping Time
< 100 nanoseconds typical
Peak Surge Currents
5,000 amps any line to ground and 5,000 amps excitation to excitation
Maximum Serial Transmission Rate
30K baud
Grounding
Through a 0.25 in lug to a 20 ft insulated #10 AWG ground wire provided
Cable Fitting
(2) Standard nylon strain relief for 0.187 to 0.312 in diameter cable
Enclosure
Chemically-resistant PVC. This device, for outdoor or indoor service, is not intended for washdown service (NEMA 4) or for submersion (NEMA 6). Optional NEMA 4X available.
Temperature
Operating: 14 °F to 104 °F (-10 °C to 40 °C)
Leakage
7,500 M ohm minimum
Dimensions
(L × W × H) 4.0 × 4.0 × 2.50 in
Warranty
One-year limited

Models & part numbers

Available configurations.

Part #Description
21143LCP-1 DC with cable compression fittings

Pricing, availability, and lead times are confirmed in your quote. Source: Rice Lake Weighing Systems 2026 Master Catalog, page 818. Specifications are subject to change without notice.