Rice Lake · Power Conditioning
Tripp-Lite DNET1
Ethernet Surge Suppressor
Standard features
- Low cost, non-serviceable
- Effective series protection for strain gauge transducers
- Encapsulated circuitry ensures positive protection against fungus or corrosion on boards
- Two nylon strain reliefs for 0.187 to 0.312 in (4.7 to 7.9 mm) diameter cable
- RJ45 input and output connections
- 5-in Ethernet patch cable enables ideal protection placed as close as possible to the point of use
- 6-in heavy gauge lead connects to designated grounding lugs on protected equipment
- Surge suppression utilizing high-speed avalanche diodes divert excess energies on the network to ground
Specifications
- Interface Type
- RJ45
- Application
- 100 Base-T, 10 Base-T, Token Ring, AS400/Sys3x, RS-422. Ideal for NICs, terminals, hubs, MAUs, LAN equipment. RJ11/45-compatible. RJ45 cable included.
- Lines Protected
- 1 to 8
- Peak Pulse Clamping Voltage
- 7.5 V NOTE: PoE not supported
- Maximum Current
- 750 amps
- Warranty
- One-year limited
- Protection Type
- Four-channel series type with separate shield
- Maximum Excitation Voltage Rate
- 18 VDC or 18 VAC
- Clamping Voltage
- 75 VDC or 75 VAC
- Clamping Time
- < 100 nanoseconds typical
- Peak Surge Currents
- 5,000 amps any line to ground and 5,000 amps excitation to excitation
- Maximum Serial Transmission Rate
- 30K baud
- Grounding
- Through a 0.25 in lug to a 20 ft insulated #10 AWG ground wire provided
- Cable Fitting
- (2) Standard nylon strain relief for 0.187 to 0.312 in diameter cable
- Enclosure
- Chemically-resistant PVC. This device, for outdoor or indoor service, is not intended for washdown service (NEMA 4) or for submersion (NEMA 6). Optional NEMA 4X available.
- Temperature
- Operating: 14 °F to 104 °F (-10 °C to 40 °C)
Models & part numbers
Available configurations.
| Part / model | Description |
|---|---|
| 72682 | DNET1 Ethernet surge suppressor 1 lb |
| 21143 | LCP-1 DC with cable compression fittings 2 lb |
Pricing, availability, and lead times are confirmed in your quote. Source: Rice Lake Weighing Systems 2026 Master Catalog, page 818. Specifications are subject to change without notice.